On Windows listener process of Classic Server can't create necessary resources after restart if any worker process was present [CORE2356] #2779
Labels
affect-version: 1.5.4
affect-version: 1.5.5
affect-version: 2.0.0
affect-version: 2.0.1
affect-version: 2.0.2
affect-version: 2.0.3
affect-version: 2.0.4
affect-version: 2.0.5
affect-version: 2.1.0
affect-version: 2.1.1
affect-version: 2.1.2
affect-version: 2.5 Alpha 1
component: engine
fix-version: 2.1.4
fix-version: 2.5 Beta 1
priority: major
qa: cannot be tested
type: bug
Submitted by: @hvlad
Run fb_inet_server -a
Connect to any database
Stop listener process via tray icon
Run fb_inet_server -a again :
you'll found XNET error in firebird.log
new connection's is not accepted until old worker process exist
The following errors could be logged in firebird.log
XNET error (xnet:2323) XNET server initialization failed
Commits: 807c777 c574a32
The text was updated successfully, but these errors were encountered: