Connection pool cleanup timer is executed only once because timer is disposed in worker method [DNET408] #409

Closed
firebird-automations opened this issue Jan 30, 2012 · 7 comments

Comments

@firebird-automations
Copy link

Submitted by: Gerdus van Zyl (angelblaze)

Attachments:
FbConnectionPool.cs.patch
FbConnectionTests.cs.patch

Expected: after time specified in ConnectionLifeTime the connection is closed.
Reality: it is not.

Connection pool cleanup timer is executed only once because timer is disposed in worker method

@firebird-automations
Copy link
Author

Commented by: Gerdus van Zyl (angelblaze)

patches to fix connection pool cleanup and add unit test

@firebird-automations
Copy link
Author

Modified by: Gerdus van Zyl (angelblaze)

Attachment: FbConnectionPool.cs.patch [ 12090 ]

Attachment: FbConnectionTests.cs.patch [ 12091 ]

@firebird-automations
Copy link
Author

Commented by: Gerdus van Zyl (angelblaze)

moved patch to attachment

@firebird-automations
Copy link
Author

Modified by: Gerdus van Zyl (angelblaze)

description: Expected: after connection pool timeout the connection is closed.
Reality: it is not.

Connection pool cleanup timer is executed only once because timer is disposed in worker method

Patch to comment out the dispose:

Index: Data/FirebirdClient/FbConnectionPool.cs

--- Data/FirebirdClient/FbConnectionPool.cs (revision 53955)
+++ Data/FirebirdClient/FbConnectionPool.cs (working copy)
@@ -314,7 +314,7 @@
}
}

- pool.cleanupTimer.Dispose();
+ <//pool.cleanupTimer.Dispose>();
}
}

=>

Expected: after connection pool timeout the connection is closed.
Reality: it is not.

Connection pool cleanup timer is executed only once because timer is disposed in worker method

@firebird-automations
Copy link
Author

Modified by: Gerdus van Zyl (angelblaze)

description: Expected: after connection pool timeout the connection is closed.
Reality: it is not.

Connection pool cleanup timer is executed only once because timer is disposed in worker method

=>

Expected: after time specified in ConnectionLifeTime the connection is closed.
Reality: it is not.

Connection pool cleanup timer is executed only once because timer is disposed in worker method

@firebird-automations
Copy link
Author

Modified by: @cincuranet

status: Open [ 1 ] => Resolved [ 5 ]

resolution: Fixed [ 1 ]

Fix Version: 2.7.1 [ 10462 ]

@firebird-automations
Copy link
Author

Modified by: @cincuranet

priority: Minor [ 4 ] => Major [ 3 ]

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment